Table 1 Scan parameters

From: Neural correlates of treatment effect and prediction of treatment outcome in patients with PTSD and comorbid personality disorder: study design

 

3D T1 – MPRAGE

Resting-state fMRI

Task-based fMRI

Multi-shell DWI

TR (ms)

6.9

2200

2200

N/A

TI (ms)

900

N/A

N/A

N/A

TE (ms)

3

28

26

81

Flip angle

9°

80°

80°

90°

# slices

168

42

42

56

# volumes

–

272

205a

80

in plane resolution (mm)

1 × 1

3.3 × 3.3

3.3 × 3.3

2.5 × 2.5

Slice thickness

1

3

3

2.5

Slice gap (mm)

N/A

0.3

0.3

N/A

Matrix size

256 × 256

64 × 64

64 × 64

96 × 96

Scan direction

N/A

Axial ascending according to HYFA

Axial ascending according to HYFA

Axial ascending According to HYFA

Shells

N/A

N/A

N/A

73 directions: interleaved 25 b1000, 24 b2000, 24 b3000 + 7 b0

  1. TR repetition time; TE echo time; TI inversion time; MPRAGE magnetization-prepared 180 degrees radio-frequency pulses and rapid gradient-echo; fMRI functional magnetic resonance imaging; HYFA imaginary straight line from the ventral hypophysis to the fastigium in the roof of the fourth ventricle.